Measured Data

Thermal Conductivity

Experiments for thermal conductivity [W/(m K)] were conducted using a heat flow meter on unconditioned and dried samples at 15 °C and either 45 °C or 65 °C.

Unconditioned

Temperature (C) Conductivity Mean (W/m-K) Standard Deviation (W/m-K)
15.0 0.053 0.0
65.0 0.064 0.0

Derived Data

Band Averaged Emissivity

Band averaged emissivity was calculated from reflectance measurements conducted with an integrating sphere and Fourier transform infrared spectrometer.

Source Temperature [K] Emissivity Std. Dev.
600.0 0.925 0.002
800.0 0.900 0.003
1000.0 0.866 0.005
1200.0 0.828 0.008
1400.0 0.791 0.011
1600.0 0.759 0.014
1800.0 0.733 0.018
2000.0 0.711 0.020