Measured Data
Specific Heat Release Rate
Experiments for specific heat release rate [W/g], were conducted using a micro-scale combustion calorimeter at a heating rate of 30 K/min.
Derived Data
Effective Heat of Combustion (Δhc)
Effective heat of combustion [MJ/kg] is calculated from data collected in micro-scale combustion calorimeter experiments.
Micro-scale Combustion Calorimeter
| Value | R1 | R2 | Mean | Std. Dev. |
|---|---|---|---|---|
| Heat of Combustion (MJ/kg) | 14.08 | 13.98 | 14.03 | 0.05 |