Measured Data

Mass Loss Rate (MLR)

Simultaneous thermal analyzer experiments were conducted at a heating rate of 10 K/min.

Simultaneous Thermal Analyzer

Specific Heat Release Rate

Micro-scale combustion calorimeter tests were conducted at a heating rate of 30 K/min.

Derived Data

Effective Heat of Combustion (Δhc)

Effective heat of combustion [MJ/kg] is calculated from data collected in micro-scale combustion calorimeter experiments.

Micro-scale Combustion Calorimeter

Value R1 R2 R3 Mean Std. Dev.
Heat of Combustion (MJ/kg) 13.35 13.24 13.47 13.35 0.09

Band Averaged Emissivity

Band averaged emissivity was calculated from reflectance measurements conducted with an integrating sphere and Fourier transform infrared spectrometer.

Source Temperature [K] Emissivity Std. Dev.
600.0 0.918 0.002
800.0 0.891 0.003
1000.0 0.858 0.005
1200.0 0.822 0.008
1400.0 0.789 0.011
1600.0 0.760 0.014
1800.0 0.736 0.017
2000.0 0.716 0.019