Measured Data
Specific Heat Release Rate
Micro-scale combustion calorimeter tests were conducted at a heating rate of 30 K/min.
Thermal Conductivity
Experiments for thermal conductivity [W/(m K)] were conducted using a heat flow meter on unconditioned and dried samples at 15 °C and either 45 °C or 65 °C.
Unconditioned
Temperature (C) | Conductivity Mean (W/m-K) | Standard Deviation (W/m-K) |
---|---|---|
15.0 | 0.113 | 0.006 |
45.0 | 0.120 | 0.006 |
Dried
Temperature (C) | Conductivity Mean (W/m-K) | Standard Deviation (W/m-K) |
---|---|---|
15.0 | 0.095 | 0.005 |
45.0 | 0.102 | 0.005 |
Mass Loss Rate (MLR)
Initial-mass-normalized mass loss rate [1/s] was measured in the simultaneous thermal analyzer experiments at three heating rates: 3 K/min, 10 K/min, and 30 K/min.
Cone calorimeter tests were conducted at a heat flux of 35 kW/m2 on samples conditioned at 20°C and 50% relative humidity.
Simultaneous Thermal Analyzer
Cone Calorimeter: 35 kW/m2
Heat Release Rate Per Unit Area (HRRPUA)
Cone calorimeter tests were conducted at a heat flux of 35 kW/m2 on samples conditioned at 20°C and 50% relative humidity.
Cone Calorimeter: 35 kW/m2
Carbon Monoxide (CO) Yield
Cone calorimeter tests were conducted at a heat flux of 35 kW/m2 on samples conditioned at 20°C and 50% relative humidity.
Incident Heat Flux [kW/m²] | Mean CO Yield [g/g] | CO Yield Std. Dev. [g/g] |
---|---|---|
35 | 0.029 | 0.013 |
Specific Heat
Experiments for specific heat [J/(kg K)], or heat capacity, were conducted using a heat flow meter on unconditioned and dried samples at 10 °C, 20 °C, 30 °C and 40 °C.
Unconditioned
Temperature (C) | Specific Heat Mean (J/kg-K) | Standard Deviation (J/kg-K) |
---|---|---|
10.0 | 1336.0 | 75.0 |
20.0 | 1383.0 | 67.0 |
30.0 | 1453.0 | 75.0 |
40.0 | 1524.0 | 83.0 |
Dried
Temperature (C) | Specific Heat Mean (J/kg-K) | Standard Deviation (J/kg-K) |
---|---|---|
10.0 | 1144.0 | 60.0 |
20.0 | 1191.0 | 69.0 |
30.0 | 1226.0 | 75.0 |
40.0 | 1281.0 | 67.0 |
Derived Data
Effective Heat of Combustion (Δhc)
Micro-scale combustion calorimeter tests were conducted at a heating rate of 30 K/min.
Cone calorimeter tests were conducted at a heat flux of 35 kW/m2 on samples conditioned at 20°C and 50% relative humidity.
Micro-scale Combustion Calorimeter
Value | R1 | R2 | R3 | Mean | Std. Dev. |
---|---|---|---|---|---|
Heat of Combustion (MJ/kg) | 11.01 | 10.84 | 11.5 | 11.12 | 0.28 |
Cone Calorimeter
Incident Heat Flux [kW/m²] | Mean Effective Heat of Combustion [MJ/kg] | Effective Heat of Combustion Std. Dev. [MJ/kg] |
---|---|---|
35 | 13.3 | 0.1 |