Measured Data
Mass Loss Rate (MLR)
Initial-mass-normalized mass loss rate [1/s] was measured in the simultaneous thermal analyzer experiments at three heating rates: 3 K/min, 10 K/min, and 30 K/min and mass loss rate [g/s] in the cone calorimeter at three heat fluxes: 25 kW/m2, 50 kW/m2, and 75 kW/m2.
Simultaneous Thermal Analyzer
Cone Calorimeter: 25 kW/m2
Cone Calorimeter: 50 kW/m2
Cone Calorimeter: 75 kW/m2
Heat Release Rate Per Unit Area (HRRPUA)
Experiments for heat release per unit area [kW/m2] were conducted on samples conditioned at 20°C and 50% relative humidity using a cone calorimeter at three different heat fluxes: 25 kW/m2, 50 kW/m2, and 75 kW/m2.
Cone Calorimeter: 25 kW/m2
| 25 kW/m² R1 | 25 kW/m² R2 | |
|---|---|---|
| Time to Sustained Ignition (s) | 6.25 | 3.00 |
| Time to Peak HRRPUA (s) | 73.00 | 57.00 |
| Peak HRRPUA (kW/m²) | 294.48 | 377.00 |
Cone Calorimeter: 50 kW/m2
| 50 kW/m² R1 | 50 kW/m² R2 | |
|---|---|---|
| Time to Sustained Ignition (s) | 2.00 | 2.75 |
| Time to Peak HRRPUA (s) | 51.25 | 36.25 |
| Peak HRRPUA (kW/m²) | 483.77 | 529.28 |
Cone Calorimeter: 75 kW/m2
| 75 kW/m² R1 | 75 kW/m² R2 | |
|---|---|---|
| Time to Sustained Ignition (s) | 1.25 | 1.25 |
| Time to Peak HRRPUA (s) | 42.50 | 39.75 |
| Peak HRRPUA (kW/m²) | 710.90 | 761.07 |
Carbon Monoxide (CO) Yield
Carbon monoxide yield was measured during cone calorimeter experiments conducted at heat fluxes of 25 kW/m2, 50 kW/m2, and 75 kW/m2.
| Incident Heat Flux [kW/m²] | Mean CO Yield [g/g] | CO Yield Std. Dev. [g/g] |
|---|---|---|
| 25 | 0.056 | 0.003 |
| 50 | 0.053 | 0.004 |
| 75 | 0.041 | 0.004 |
Derived Data
Soot Yield
Soot yield [g/g] was calculated from smoke obscuration data collected in cone calorimeter experiments conducted at heat fluxes of 25 kW/m2, 50 kW/m2, and 75 kW/m2.
| Incident Heat Flux [kW/m²] | Mean Soot Yield [g/g] | Soot Yield Std. Dev. [g/g] |
|---|---|---|
| 25 | 0.096 | 0.001 |
| 50 | 0.095 | 0.004 |
| 75 | 0.079 | 0.004 |
Effective Heat of Combustion (Δhc)
Effective heat of combustion [MJ/kg] is calculated from data collected in cone calorimeter experiments.
Cone Calorimeter
| Incident Heat Flux [kW/m²] | Mean Effective Heat of Combustion [MJ/kg] | Effective Heat of Combustion Std. Dev. [MJ/kg] |
|---|---|---|
| 25 | 19.4 | 0.6 |
| 50 | 20.0 | 0.2 |
| 75 | 19.2 | 2.6 |