Measured Data
Mass Loss Rate (MLR)
Simultaneous thermal analyzer experiments were conducted at three heating rates: 3 K/min, 10 K/min, and 30 K/min.
Simultaneous Thermal Analyzer
Specific Heat Release Rate
Micro-scale combustion calorimeter tests were conducted at a heating rate of 30 K/min.
Derived Data
Effective Heat of Combustion (Δhc)
Effective heat of combustion [MJ/kg] is calculated from data collected in micro-scale combustion calorimeter experiments.
Micro-scale Combustion Calorimeter
| Value | R1 | R2 | R3 | Mean | Std. Dev. |
|---|---|---|---|---|---|
| Heat of Combustion (MJ/kg) | 10.61 | 9.83 | 9.87 | 10.1 | 0.36 |
Band Averaged Emissivity
Band averaged emissivity was calculated from reflectance measurements conducted with an integrating sphere and Fourier transform infrared spectrometer.
| Source Temperature [K] | Emissivity | Std. Dev. |
|---|---|---|
| 600.0 | 0.846 | 0.003 |
| 800.0 | 0.805 | 0.004 |
| 1000.0 | 0.756 | 0.007 |
| 1200.0 | 0.704 | 0.011 |
| 1400.0 | 0.656 | 0.015 |
| 1600.0 | 0.615 | 0.020 |
| 1800.0 | 0.582 | 0.024 |
| 2000.0 | 0.554 | 0.028 |